Configuring a Schlage Handkey II for verification


How Do I configure the Biometric HandKey RSI for Verification?

1.       Check that the firmware installed in the 500B is the firmware for RSI. There are three firmwares available for 500B: RSI, Bioscript and Identix

2.       Enter the setup in the Handkey RSI by pressing CLEAR+ENTER

3.       The default password is 2

4.       SET LANGUAGE: set the language, default is English

5.       SET DATE FORMAT: set the Data and Time Format

6.       SET TIME AND DATE: set the Time and Date

7.       SET ADDRESS:

a.       Unit Adress: Set the address of the unit depending on the Port is connection from the 500B

b.       From Port 2 from LNL-500B:

                                                               i.      reader address in this order Reader 0, Reader 1, Reader 2, Reader 3.

c.       From Port 3 from LNL-500B:

                                                               i.      Reader 4, Reader 5, Reader 6, Reader 7.

8.       SET ID LENGTH: don’t need to configure

9.       FACILITY: don’t need to configure

10.   AUX CONTROL: don’t need to configure

11.   READER MODE: Remote

12.   SERIAL: Yes

a.       485: Yes

b.       Baud: 19200

c.       232: Yes

d.       Baud: anything
 

e.       USE RS-232 for: Printer

13.   DURESS: don’t need to configure

14.   BEEPER: don’t need to configure

15.   In OnGuard:

a.       Access Panel: Options: RSI Biometrics

b.       System Options: Biometrics: Set Maximum Templates and Default minimum score.

c.       In readers, in the biometric  reader, select the Primary Reader

d.       In readers, set Biometric Verify on the primary reader (the reader that is not the biometric, but is attached to the biometric reader)

16.   In Alarm Monitoring, under Options, Display Controller Capacity. Check the number of templates stored in the panel. If not templates are in the panel, it will not request the biometric template (hand) when you swipe a badge.